High Efficiency Furnace Pressure Switch Problems

Top 10 Gas Furnace Pressure Switch Error Code Problems Youtube

Top 10 Gas Furnace Pressure Switch Error Code Problems Youtube

Gas Furnace Troubleshooting Pressure Switch Testing Condensate Problem Error Codes Youtube

Gas Furnace Troubleshooting Pressure Switch Testing Condensate Problem Error Codes Youtube

Diy How To Temporary Fix Furnace Pressure Switch Youtube

Diy How To Temporary Fix Furnace Pressure Switch Youtube

Gas Furnace Pressure Switch Problems Gray Furnaceman Furnace Troubleshoot And Repair

Gas Furnace Pressure Switch Problems Gray Furnaceman Furnace Troubleshoot And Repair

How To Jump Pressure Switch On Furnace Youtube

How To Jump Pressure Switch On Furnace Youtube

Furnace Pressure Switch Repair And Replace Youtube

Furnace Pressure Switch Repair And Replace Youtube

Furnace Pressure Switch Repair And Replace Youtube

A partially clogged flue vent condensate line or a clog at the condensate collector box near the inducer fan will often trip the furnace s pressure switch.

High efficiency furnace pressure switch problems.

Of course the pressure switch may also shut down if the motor is old and running too slow to satisfy the switch or the hose from the fan to the switch is pinched or broken or the switch itself is bad. If the condensate drain is blocked by debris or frozen condensate or it simply drains improperly the pressure switch may open preventing ignition. If your pressure switch is stuck it is most likely a problem in the running of the furnace. A crack in the heat exchanger could also be at fault.

First off the furnace being high efficient will produce water due to low vent temperatures and condensation in the vent pipe. You can disconnect the pressure switch tubing so it will not get damaged and suck the condensate drain line out with a wet vac. Holes tears or other damage to the diaphragm. The plunger may not be pulling in completely and may only bob around when the pressure builds up inside the furnace.

1 a restricted vent pipe 2 too long of vent piping and too many turns which exceeds manufacturer s recommendations 3 a stopped up condensate drain line if you have a high efficiency condensing furnace. Water in the vent due to a sag in the piping could cause a pressure switch not to close. Problems a furnace pressure switch can develop. Pressure switches may act up for several reasons including.

Pressure switch fail open first and most obvious would be failed ventor motor check 110 volts to motor and if it has seized. Ice on the venting or a plugged screen on the vent termination only on 90 efficient furnaces could also be the problem. If you have a high efficiency furnace then you probably have a condensate drain and if the condensate drain becomes clogged up it will cause pressure switch problems. The most common problem on high efficient furnaces would be frost or water in the vent.

Coated or stiffened pressure switch diaphragm. Old age which can cause inaccurate readings and faulty furnace cycling. 4 a dirty or stopped up draft inducer.

Furnace Pressure Switch Testing How To

Furnace Pressure Switch Testing How To

Hvac Pressure Switch Opened Or Closed Youtube

Hvac Pressure Switch Opened Or Closed Youtube

Fix For Clogged Drainage Error Code 31 On Bryant High Efficiency Gas Furnace Permanent Repair Youtube

Fix For Clogged Drainage Error Code 31 On Bryant High Efficiency Gas Furnace Permanent Repair Youtube

Furnace Pressure Switch Troubleshooting Youtube

Furnace Pressure Switch Troubleshooting Youtube

Source : pinterest.com